Modulation technique
Cenelec A-band
- 60 subcarrier OFDM.
- Modulation: Differential QPSK, 2 bit/symbol.
- Used bandwidth: 30-88 kHz.
- Carrier spacing: 966 Hz.
- Effective Line rate: 16 kbit/s.
Operating mode
- Half-duplex.
- Point-to-point.
- Multidrop/Multipoint.
Transmitter
- Output impedance:
< 3Ω (when transmitting).
- Output level in
Cenelec bands: 7V(p-p) in [50
µH + 5Ω // 50Ω] load.
Receiver
- Sensitivity: <
400µV(p-p).
- Dynamic range: >
80dB.
- Impedance: 235Ω .
Serial interface
- RS-232 at DB9
connector.
- Supported signals: TxD, RxD, RTS,
CTS, DSR and DCD.
- RS-422/RS-485 at
screw terminal connector.
Supported serial
data
rates
- Asynchronous: 300,
600, 1200, 2400, 4800, 7200, 9600, 19k2, 38k4, 57k6, 115k2 bps
Data formats: 10 and 11 bits.
- Packet size: Up to
300 characters.
- Data rate and format
set by means of DIP switches.
Line connection
- 2-wire screw
terminal connector for direct connection to LV lines (Up to 240Vac).
- External coupler
for 3-phase (400Vac) lines.
- External inductive
coupler for shielded MV cable.
- Capacitive couplers
for MV and HV lines available on request.
Housing
- Compact
plastic housing suitable for panel or DINrail mounting.
Dimensions and weight
- PLM-501D:
95x145x30 mm LxWxH, Weight: 280 gr.
Power Supply and
Environment
- Power supply input:
18..75
Vdc (12..50Vac) (20 Watts max.) .
- Temperature
range:
-25..+70°C, Humidity: 5..95%
Safety
- Isolation between
Serial ports and Power supply: 3000Vac.
- Isolation between Line/coupler and Power supply:
4000Vac.
- Isolation between
Serial ports and Line/coupler:
7000Vac.
Compliances
- CE mark: 2004/108/EC, 2006/95/EC, EN55022, EN50082-2,
EN55024, EN60950.
- Line operation : CENELEC EN 50065-1, FCC or MPT.
- Climate: EN50125-3.
- Vibration: EN50125-3.
Ordering
Cenelec A-band
operation:
PLM-501D-A.
(Other operating bands available on request)
|